Earthing and Short-Circuiting Devices for Crane Conductor Bars
![](/thumbor/unsafe/fit-in/480x/filters:fill(ffffff,false):quality(98)/dehn.de/store/f/44122273/HDVORSCHAU/745370a1_16-9.jpg)
![](/thumbor/unsafe/fit-in/1280x720/filters:fill(ffffff,false):quality(98)/dehn.de/store/f/44122273/HDVORSCHAU/745370a1_16-9.jpg)
- For insulated or bare conductor bars of cranes and lifting equipment
- Allows to lock the clamping range of the clamps in several positions
- Waterproof, plastic-sheathed cable entries and node unit, with additional ant-kink protection
- Other cable lengths can be selected online via the earthing and short-circuiting configurator
Details
![](/thumbor/unsafe/fit-in/300x300/filters:fill(ffffff,false):quality(98)/dehn.de/store/f/44122274/HDVORSCHAU/745370az1.jpg)
![lorem ipsum](/thumbor/unsafe/fit-in/1280x/filters:fill(ffffff,false):quality(98)/dehn.de/store/f/44122274/HDVORSCHAU/745370az1.jpg)
![](/thumbor/unsafe/fit-in/300x300/filters:fill(ffffff,false):quality(98)/dehn.de/store/f/44122275/HDVORSCHAU/745375az1.jpg)
![lorem ipsum](/thumbor/unsafe/fit-in/1280x/filters:fill(ffffff,false):quality(98)/dehn.de/store/f/44122275/HDVORSCHAU/745375az1.jpg)
Art.-Nr. VH8QTCZ EKV3 25IS ZK VH8QTCZ
GTIN 4013364163775, Zolltarifnr. (EU): 85359000, Bruttogewicht: 5.59 kg, VPE: 1.00 pc(s)
Technische Daten
Clamping range | 55 mm |
Max. short-circuit current Ik 0.5 s | 7.0 kA |
Max. short-circuit current Ik 1 s | 4.9 kA |
Attention: Please state the relevant Variant No. when ordering. |
Art.-Nr. VKB2Q6J EKV3 35IS ZK VKB2Q6J
GTIN 4013364163829, Zolltarifnr. (EU): 85359000, Bruttogewicht: 5.75 kg, VPE: 1.00 pc(s)
Technische Daten
Clamping range | 55 mm |
Max. short-circuit current Ik 0.5 s | 10.0 kA |
Max. short-circuit current Ik 1 s | 6.9 kA |
Attention: Please state the relevant Variant No. when ordering. |
Art.-Nr. VP6YV4T EKV3 50IS ZK VP6YV4T
GTIN 4013364162686, Zolltarifnr. (EU): 85359000, Bruttogewicht: 6.30 kg, VPE: 1.00 pc(s)
Technische Daten
Clamping range | 55 mm |
Max. short-circuit current Ik 0.5 s | 14.0 kA |
Max. short-circuit current Ik 1 s | 9.9 kA |
Attention: Please state the relevant Variant No. when ordering. |
Art.-Nr. VQKTK4T EKV3 25BS ZK VQKTK4T
GTIN 4013364163768, Zolltarifnr. (EU): 85359000, Bruttogewicht: 5.40 kg, VPE: 1.00 pc(s)
Technische Daten
Clamping range | 85 mm |
Max. short-circuit current Ik 0.5 s | 7.0 kA |
Max. short-circuit current Ik 1 s | 4.9 kA |
Attention: Please state the relevant Variant No. when ordering. |
Art.-Nr. VN63A91 EKV3 35BS ZK VN63A91
GTIN 4013364163812, Zolltarifnr. (EU): 85359000, Bruttogewicht: 5.56 kg, VPE: 1.00 pc(s)
Technische Daten
Clamping range | 85 mm |
Max. short-circuit current Ik 0.5 s | 10.0 kA |
Max. short-circuit current Ik 1 s | 6.9 kA |
Attention: Please state the relevant Variant No. when ordering. |