Earthing Sticks for Overhead Lines
![](/thumbor/unsafe/fit-in/480x/filters:fill(ffffff,false):quality(98)/dehn.de/store/f/45434624/HDVORSCHAU/784401a0004.jpg)
![](/thumbor/unsafe/fit-in/1280x720/filters:fill(ffffff,false):quality(98)/dehn.de/store/f/45434624/HDVORSCHAU/784401a0004.jpg)
- For outdoor use
- Robust aluminium cone coupling
- Total lengths up to 6000 mm
- Telescopic stick, length continuously adjustable by star knob
- For phase screw clamps and clamps with long T pin shaft
Details
![](/thumbor/unsafe/fit-in/300x300/filters:fill(ffffff,false):quality(98)/dehn.de/store/f/45434628/HDVORSCHAU/769500_1.jpg)
The adjusting ring on the cone has the following functions:
– Position "AUF" (= OPEN): Stick can be removed after the clamp has been attached
– Position "ZU" (= CLOSED): Stick and clamp remain coupled even after the earthing and short-circuiting device has been attached
![lorem ipsum](/thumbor/unsafe/fit-in/1280x/filters:fill(ffffff,false):quality(98)/dehn.de/store/f/45434628/HDVORSCHAU/769500_1.jpg)
![](/thumbor/unsafe/fit-in/300x300/filters:fill(ffffff,false):quality(98)/dehn.de/store/f/45434629/HDVORSCHAU/769504_1.jpg)
![lorem ipsum](/thumbor/unsafe/fit-in/1280x/filters:fill(ffffff,false):quality(98)/dehn.de/store/f/45434629/HDVORSCHAU/769504_1.jpg)
![](/thumbor/unsafe/fit-in/300x300/filters:fill(ffffff,false):quality(98)/dehn.de/store/f/45434626/HDVORSCHAU/769503_Kopflast_E.jpg)
![lorem ipsum](/thumbor/unsafe/fit-in/1280x/filters:fill(ffffff,false):quality(98)/dehn.de/store/f/45434626/HDVORSCHAU/769503_Kopflast_E.jpg)
![](/thumbor/unsafe/fit-in/300x300/filters:fill(ffffff,false):quality(98)/dehn.de/store/f/45434627/HDVORSCHAU/766617_4.jpg)
![lorem ipsum](/thumbor/unsafe/fit-in/1280x/filters:fill(ffffff,false):quality(98)/dehn.de/store/f/45434627/HDVORSCHAU/766617_4.jpg)
![](/thumbor/unsafe/fit-in/300x300/filters:fill(ffffff,false):quality(98)/dehn.de/store/f/45434625/HDVORSCHAU/784401a2.jpg)
![lorem ipsum](/thumbor/unsafe/fit-in/1280x/filters:fill(ffffff,false):quality(98)/dehn.de/store/f/45434625/HDVORSCHAU/784401a2.jpg)
Art.-Nr. 769400 ESTC SQL 4000
GTIN 4013364080881, Zolltarifnr. (EU): 82055980, Bruttogewicht: 4.42 kg, VPE: 1.00 pc(s)
Technische Daten
Total length (lG max / IG min ) | 4015 / 2180 mm |
Length (handle) (IH ) | 1400 mm |
Max. load on the operating head (lG max / IG min ) | 10 / 20 kg |
Diameter | 43 mm |
Art.-Nr. 769500 ESTC SQL 5000
GTIN 4013364080904, Zolltarifnr. (EU): 82055980, Bruttogewicht: 5.02 kg, VPE: 1.00 pc(s)
Technische Daten
Total length (lG max / IG min ) | 5015 / 2680 mm |
Length (handle) (IH ) | 1900 mm |
Max. load on the operating head (lG max / IG min ) | 10 / 20 kg |
Diameter | 43 mm |
Art.-Nr. 769300 ESTC SQL STK 3000
GTIN 4013364080867, Zolltarifnr. (EU): 82055980, Bruttogewicht: 3.80 kg, VPE: 1.00 pc(s)
Technische Daten
Total length (lG max / IG min ) | 3015 / 1760 mm |
Length (handle) (IH ) | 900 mm |
Max. load on the operating head (lG max / IG min ) | 10 / 20 kg |
Diameter | 43 mm |
Art.-Nr. 769503 EST KS SQL 1500
GTIN 4013364003996, Zolltarifnr. (EU): 82055980, Bruttogewicht: 2.39 kg, VPE: 1.00 pc(s)
Technische Daten
Total length (lG ) | 1600 mm |
Max. load on the operating head | 20 kg |
Diameter | 43 mm |
Art.-Nr. 769504 EST ZS 1500
GTIN 4013364004559, Zolltarifnr. (EU): 82055980, Bruttogewicht: 2.39 kg, VPE: 1.00 pc(s)
Technische Daten
Total length (lG ) | 1580 mm |
Diameter | 43 mm |
Art.-Nr. 769505 EST ES 1500
GTIN 4013364004566, Zolltarifnr. (EU): 82055980, Bruttogewicht: 2.46 kg, VPE: 1.00 pc(s)
Technische Daten
Total length (lG ) | 1590 mm |
Diameter | 43 mm |