Ihre Services im Dashboard..
Registriert nutzen Sie das komplette Angebot.

Cross Units for Aboveground and Underground Connections

of conductors in cross, parallel and T arrangement.

With intermediate plate, for round and flat conductors

3 Produkte

Art.-Nr. 319201 KS 8.10 8.10 FL30 ZP STTZN

GTIN 4013364024519, Zolltarifnr. (EU): 85359000, Bruttogewicht: 324.00 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Cross units with intermediate plate for round and flat conductors, HDG steel
Cross units for aboveground and
underground connections
for connecting conductors
in cross, parallel and T arrangement
Material of clamp: St/tZn
Clamping range Rd / Rd: 8-10 / 8-10 mm
Clamping range Rd / Fl: 8-10 / 30 mm
Clamping range Fl / Fl: 30 / 30 mm
Material of screw / nut: St/tZn
Intermediate plate: yes
Standard: EN 62561-1

Brand: DEHN
Type: KS 8.10 8.10 FL30 ZP STTZN
Part No.: 319201
or equivalent.

Zertifikate

 

Technische Daten

Material of clamp St/tZn
Clamping range Rd / Rd 8-10 / 8-10 mm
Clamping range Rd / Fl 8-10 / 30 mm
Clamping range Fl / Fl 30 / 30 mm
Dimensions 60 x 60 x 3 mm
Standard EN 62561-1
Short-circuit current (AC 50 Hz / DC) (1 s; ≤ 300 °C) 14 kA
*) See test certificate for exact classification.

Artikel 319201 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 319201 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 319207 KS 8.10 8.10 FL30 ZP CU

GTIN 4013364020047, Zolltarifnr. (EU): 85359000, Bruttogewicht: 353.00 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Cross units with intermediate plate for round and flat conductors, Cu
Cross units for aboveground and
underground connections
for connecting conductors
in cross, parallel and T arrangement
Material of clamp: Cu
Clamping range Rd / Rd: 8-10 / 8-10 mm
Clamping range Rd / Fl: 8-10 / 30 mm
Clamping range Fl / Fl: 30 / 30 mm
Material of screw / nut: StSt (V4A)
Material No.: 1.4571 / 1.4404 / 1.4401
ASTM / AISI:: 316Ti / 316L / 316
Intermediate plate: yes
Standard: EN 62561-1

Brand: DEHN
Type: KS 8.10 8.10 FL30 ZP CU
Part No.: 319207
or equivalent.

Zertifikate

 

Technische Daten

Material of clamp Cu
Clamping range Rd / Rd 8-10 / 8-10 mm
Clamping range Rd / Fl 8-10 / 30 mm
Clamping range Fl / Fl 30 / 30 mm
Clamping range (stranded / cable) 35-70 mm2
ASTM / AISI: 316Ti / 316L / 316
Dimensions 60 x 60 x 3 mm
Standard EN 62561-1
Short-circuit current (AC 50 Hz / DC) (1 s; ≤ 300 °C) 29 kA
*) See test certificate for exact classification.

Artikel 319207 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 319207 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 319209 KS 8.10 8.10 FL30 ZP V4A

GTIN 4013364035980, Zolltarifnr. (EU): 85359000, Bruttogewicht: 316.90 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Cross units with intermediate plate for round and flat conductors, StSt (V4A)
Cross units for aboveground and
underground connections
for connecting conductors
in cross, parallel and T arrangement

Material of clamp: StSt (V4A)
Clamping range Rd / Rd: 8-10 / 8-10 mm
Clamping range Rd / Fl: 8-10 / 30 mm
Clamping range Fl / Fl: 30 / 30 mm
Material of screw / nut: StSt (V4A)
Material No.: 1.4571 / 1.4404 / 1.4401
ASTM / AISI:: 316Ti / 316L / 316
Intermediate plate: yes
Standard: EN 62561-1

Brand: DEHN
Type: KS 8.10 8.10 FL30 ZP V4A
Part No.: 319209
or equivalent.

Zertifikate

 

Technische Daten

Material of clamp StSt (V4A)
Clamping range Rd / Rd 8-10 / 8-10 mm
Clamping range Rd / Fl 8-10 / 30 mm
Clamping range Fl / Fl 30 / 30 mm
Clamping range (stranded / cable) 35-70 mm2
ASTM / AISI: 316Ti / 316L / 316
Dimensions 60 x 60 x 3 mm
Standard EN 62561-1
Short-circuit current (AC 50 Hz / DC) (1 s; ≤ 300 °C) 7 kA
*) See test certificate for exact classification.

Artikel 319209 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 319209 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

With intermediate plate, for round and flat conductors up to 40 mm

2 Produkte

Art.-Nr. 321045 KS 8.10 FL40 STTZN

GTIN 4013364021518, Zolltarifnr. (EU): 85359000, Bruttogewicht: 417.80 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

cross units with intermediate plate for round and flat conductors up to 40 mm
Cross units for aboveground and
underground connections
for connecting conductors
in cross, parallel and T arrangement
Material of clamp: St/tZn
Clamping range Rd / Fl: 8-10 / 30-40 mm
Clamping range Fl / Fl: 30-40 / 30-40 mm
Material of screw / nut: St/tZn
Intermediate plate: yes
Standard: EN 62561-1

Brand: DEHN
Type: KS 8.10 FL40 STTZN
Part No.: 321045
or equivalent.

Zertifikate

 

Technische Daten

Material of clamp St/tZn
Clamping range Rd / Fl 8-10 / 30-40 mm
Clamping range Fl / Fl 30-40 / 30-40 mm
Dimensions 70 x 70 x 3 mm
Standard EN 62561-1
Short-circuit current (AC 50 Hz / DC) (1 s; ≤ 300 °C) 12.6 kA
*) See test certificate for exact classification.

Artikel 321045 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 321045 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 321047 KS 8.10 FL40 CU

GTIN 4013364021525, Zolltarifnr. (EU): 85359000, Bruttogewicht: 457.80 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

cross units with intermediate plate for round and flat conductors up to 40 mm
Cross units for aboveground and
underground connections
for connecting conductors
in cross, parallel and T arrangement
Material of clamp: Cu
Clamping range Rd / Fl: 8-10 / 30-40 mm
Clamping range Fl / Fl: 30-40 / 30-40 mm
Material of screw / nut: StSt (V4A)
Material No.: 1.4571 / 1.4404 / 1.4401
ASTM / AISI:: 316Ti / 316L / 316
Intermediate plate: yes
Standard: EN 62561-1

Brand: DEHN
Type: KS 8.10 FL40 CU
Part No.: 321047
or equivalent.

Zertifikate

 

Technische Daten

Material of clamp Cu
Clamping range Rd / Fl 8-10 / 30-40 mm
Clamping range Fl / Fl 30-40 / 30-40 mm
Clamping range (stranded / cable) 35-120 mm2
ASTM / AISI: 316Ti / 316L / 316
Dimensions 70 x 70 x 3 mm
Standard EN 62561-1
Short-circuit current (AC 50 Hz / DC) (1 s; ≤ 300 °C) 35.1 kA
*) See test certificate for exact classification.

Artikel 321047 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 321047 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

With intermediate plate, for two round and flat conductors up to 40 mm

1 Produkt

Art.-Nr. 319229 KS 7.10 7.10 FL40 ZP V4A

GTIN 4013364108752, Zolltarifnr. (EU): 85359000, Bruttogewicht: 413.80 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

cross units with intermediate plate for two round and flat conductors up to 40 mm
Cross units for aboveground and
underground connections
for connecting conductors
in cross, parallel and T arrangement
with intermediate plate for
round and flat up to 40 mm
Material of clamp: StSt (V4A)
Clamping range Rd / Rd: 7-10 / 7-10 mm
Clamping range Rd / Fl: 7-10 / 30-40 mm
Clamping range Fl / Fl: 30-40 / 30-40 mm
Material of screw / nut: StSt (V4A)
Material No.: 1.4571 / 1.4404 / 1.4401
ASTM / AISI:: 316Ti / 316L / 316
Intermediate plate: yes
Standard: EN 62561-1

Brand: DEHN
Type: KS 7.10 7.10 FL40 ZP V4A
Part No.: 319229
or equivalent.

Zertifikate

 

Technische Daten

Material of clamp StSt (V4A)
Clamping range Rd / Rd 7-10 / 7-10 mm
Clamping range Rd / Fl 7-10 / 30-40 mm
Clamping range Fl / Fl 30-40 / 30-40 mm
Clamping range (stranded / cable) 35-95 mm2
ASTM / AISI: 316Ti / 316L / 316
Dimensions 70 x 70 x 3 mm
Standard EN 62561-1
Short-circuit current (AC 50 Hz / DC) (1 s; ≤ 300 °C) 5.0 kA
*) See test certificate for exact classification.

Artikel 319229 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 319229 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

With intermediate plate, for earth entries / air-termination rods

2 Produkte

Art.-Nr. 319202 KS 8.10 16 FL30 ZP STTZN

GTIN 4013364024526, Zolltarifnr. (EU): 85359000, Bruttogewicht: 337.80 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Cross units with intermediate plate for earth entry/air-termination rods
Cross units for aboveground and
underground connections
for connecting conductors
in cross, parallel and T arrangement
to earth entry or air-termination rods
Material of clamp: St/tZn
Clamping range Rd / Rd: 16 / 8-10 mm
Clamping range Rd / Fl: 16 / 30 mm
Material of screw / nut: St/tZn
Intermediate plate: yes
Standard: EN 62561-1

Brand: DEHN
Type: KS 8.10 16 FL30 ZP STTZN
Part No.: 319202
or equivalent.

Zertifikate

 

Technische Daten

Material of clamp St/tZn
Clamping range Rd / Rd 16 / 8-10 mm
Clamping range Rd / Fl 16 / 30 mm
Dimensions 60 x 60 x 3 mm
Standard EN 62561-1
*) See test certificate for exact classification.

Artikel 319202 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 319202 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 319219 KS 8.10 16 FL30 ZP V4A

GTIN 4013364069916, Zolltarifnr. (EU): 85359000, Bruttogewicht: 323.90 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Cross units with intermediate plate for earth entry/air-termination rods
Cross units for aboveground and
underground connections
for connecting conductors
in cross, parallel and T arrangement
to earth entry or air-termination rods
Material of clamp: StSt (V4A)
Clamping range Rd / Rd: 16 / 8-10 mm
Clamping range Rd / Fl: 16 / 30 mm
Material of screw / nut: StSt (V4A)
Material No.: 1.4571 / 1.4404 / 1.4401
ASTM / AISI:: 316Ti / 316L / 316
Intermediate plate: yes
Standard: EN 62561-1

Brand: DEHN
Type: KS 8.10 16 FL30 ZP V4A
Part No.: 319219
or equivalent.

Zertifikate

 

Technische Daten

Material of clamp StSt (V4A)
Clamping range Rd / Rd 16 / 8-10 mm
Clamping range Rd / Fl 16 / 30 mm
Clamping range (stranded / cable) 35-120 mm2
ASTM / AISI: 316Ti / 316L / 316
Dimensions 60 x 60 x 3 mm
Standard EN 62561-1
*) See test certificate for exact classification.

Artikel 319219 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 319219 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Without intermediate plate, for round and flat conductors

3 Produkte

Art.-Nr. 318201 KS 8.10 FL30 STTZN

GTIN 4013364021464, Zolltarifnr. (EU): 85359000, Bruttogewicht: 238.00 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Cross units without intermediate plate for round and flat conductors, HDG steel
Cross units for aboveground and
underground connections
for connecting conductors
in cross, parallel and T arrangement
Material of clamp: St/tZn
Clamping range Rd / Fl: 8-10 / 30 mm
Clamping range Fl / Fl: 30 / 30 mm
Material of screw / nut: St/tZn
Standard: EN 62561-1

Brand: DEHN
Type: KS 8.10 FL30 STTZN
Part No.: 318201
or equivalent.

Zertifikate

 

Technische Daten

Material of clamp St/tZn
Clamping range Rd / Fl 8-10 / 30 mm
Clamping range Fl / Fl 30 / 30 mm
Dimensions 60 x 60 x 3 mm
Standard EN 62561-1
Short-circuit current (AC 50 Hz / DC) (1 s; ≤ 300 °C) 14 kA
*) See test certificate for exact classification.

Artikel 318201 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 318201 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 318207 KS 8.10 FL30 CU

GTIN 4013364021488, Zolltarifnr. (EU): 85359000, Bruttogewicht: 257.00 g, VPE: 1.00 pc(s)


Abbildungen

Weitere Information

Cross units without intermediate plate for round and flat conductors, Cu
Cross units for aboveground and
underground connections
for connecting conductors
in cross, parallel and T arrangement
Material of clamp: Cu
Clamping range Rd / Fl: 8-10 / 30 mm
Clamping range Fl / Fl: 30 / 30 mm
Material of screw / nut: StSt (V4A)
Material No.: 1.4571 / 1.4404 / 1.4401
ASTM / AISI:: 316Ti / 316L / 316
Standard: EN 62561-1

Brand: DEHN
Type: KS 8.10 FL30 CU
Part No.: 318207
or equivalent.

Zertifikate

 

Technische Daten

Material of clamp Cu
Clamping range Rd / Fl 8-10 / 30 mm
Clamping range Fl / Fl 30 / 30 mm
Clamping range (stranded / cable) 35-120 mm2
ASTM / AISI: 316Ti / 316L / 316
Dimensions 60 x 60 x 3 mm
Standard EN 62561-1
Short-circuit current (AC 50 Hz / DC) (1 s; ≤ 300 °C) 29 kA
*) See test certificate for exact classification.

Artikel 318207 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 318207 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 318209 KS 8.10 FL30 V4A

GTIN 4013364035973, Zolltarifnr. (EU): 85359000, Bruttogewicht: 249.40 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Cross units without intermediate plate for round and flat conductors, StSt (V4A)
Cross units for aboveground and
underground connections
for connecting conductors
in cross, parallel and T arrangement
Material of clamp: StSt (V4A)
Clamping range Rd / Fl: 8-10 / 30 mm
Clamping range Fl / Fl: 30 / 30 mm
Material of screw / nut: StSt (V4A)
Material No.: 1.4571 / 1.4404 / 1.4401
ASTM / AISI:: 316Ti / 316L / 316
Standard: EN 62561-1

Brand: DEHN
Type: KS 8.10 FL30 V4A
Part No.: 318209
or equivalent.

Zertifikate

 

Technische Daten

Material of clamp StSt (V4A)
Clamping range Rd / Fl 8-10 / 30 mm
Clamping range Fl / Fl 30 / 30 mm
Clamping range (stranded / cable) 35-120 mm2
ASTM / AISI: 316Ti / 316L / 316
Dimensions 60 x 60 x 3 mm
Standard EN 62561-1
Short-circuit current (AC 50 Hz / DC) (1 s; ≤ 300 °C) 7.4 kA
*) See test certificate for exact classification.

Artikel 318209 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 318209 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Without intermediate plate, for two round and flat conductors

2 Produkte

Art.-Nr. 318251 KS 8.10 8.10 FL30 STTZN

GTIN 4013364046559, Zolltarifnr. (EU): 85359000, Bruttogewicht: 245.00 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Cross units without intermediate plate for two round and flat conductors HDG steel
Cross units for aboveground and
underground connections
for connecting conductors
in cross, parallel and T arrangement
Material of clamp: St/tZn
Clamping range Rd / Rd: 8-10 / 8-10 mm
Clamping range Rd / Fl: 8-10 / 30 mm
Clamping range Fl / Fl: 30 / 30 mm
Material of screw / nut: St/tZn
Standard: EN 62561-1

Brand: DEHN
Type: KS 8.10 8.10 FL30 STTZN
Part No.: 318251
or equivalent.

Zertifikate

 

Technische Daten

Material of clamp St/tZn
Clamping range Rd / Rd 8-10 / 8-10 mm
Clamping range Rd / Fl 8-10 / 30 mm
Clamping range Fl / Fl 30 / 30 mm
Dimensions 60 x 60 x 3 mm
Standard EN 62561-1
Short-circuit current (AC 50 Hz / DC) (1 s; ≤ 300 °C) 14 kA
*) See test certificate for exact classification.

Artikel 318251 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 318251 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 318219 KS 8.10 8.10 FL30 V4A

GTIN 4013364129320, Zolltarifnr. (EU): 85359000, Bruttogewicht: 239.00 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Cross units without intermediate plate for two round and flat conductors StSt
Cross units for aboveground and
underground connections
for connecting conductors
in cross, parallel and T arrangement
Material of clamp: StSt (V4A)
Clamping range Rd / Rd: 8-10 / 8-10 mm
Clamping range Rd / Fl: 8-10 / 30 mm
Clamping range Fl / Fl: 30 / 30 mm
Material of screw / nut: StSt (V4A)
Material No.: 1.4571 / 1.4404 / 1.4401
ASTM / AISI:: 316Ti / 316L / 316
Standard: EN 62561-1

Brand: DEHN
Type: KS 8.10 8.10 FL30 V4A
Part No.: 318219
or equivalent.

Zertifikate

 

Technische Daten

Material of clamp StSt (V4A)
Clamping range Rd / Rd 8-10 / 8-10 mm
Clamping range Rd / Fl 8-10 / 30 mm
Clamping range Fl / Fl 30 / 30 mm
Clamping range (stranded / cable) 35-120 mm2
ASTM / AISI: 316Ti / 316L / 316
Dimensions 60 x 60 x 3 mm
Standard EN 62561-1
Short-circuit current (AC 50 Hz / DC) (1 s; ≤ 300 °C) 7.4 kA
*) See test certificate for exact classification.

Artikel 318219 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 318219 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Without intermediate plate, for two flat conductors

2 Produkte

Art.-Nr. 318033 KS FL30 STTZN

GTIN 4013364021471, Zolltarifnr. (EU): 85359000, Bruttogewicht: 240.00 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Cross units without intermediate plate for two flat conductors, HDG steel
Cross units for aboveground and
underground connections
for connecting conductors
in cross, parallel and T arrangement
Material of clamp: St/tZn
Clamping range Fl / Fl: 30 / 30 mm
Material of screw / nut: St/tZn
Standard: EN 62561-1

Brand: DEHN
Type: KS FL30 STTZN
Part No.: 318033
or equivalent.

Zertifikate

 

Technische Daten

Material of clamp St/tZn
Clamping range Fl / Fl 30 / 30 mm
Dimensions 60 x 60 x 3 mm
Standard EN 62561-1
Short-circuit current (AC 50 Hz / DC) (1 s; ≤ 300 °C) 8.4 kA
*) See test certificate for exact classification.

Artikel 318033 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 318033 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 318233 KS FL30 V4A

GTIN 4013364096646, Zolltarifnr. (EU): 85359000, Bruttogewicht: 229.30 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Cross units without intermediate plate for two flat conductors, StSt (V4A)
Cross units for aboveground and
underground connections
for connecting conductors
in cross, parallel and T arrangement
Material of clamp: StSt (V4A)
Clamping range Fl / Fl: 30 / 30 mm
Material of screw / nut: StSt (V4A)
Material No.: 1.4571 / 1.4404 / 1.4401
ASTM / AISI:: 316Ti / 316L / 316
Standard: EN 62561-1

Brand: DEHN
Type: KS FL30 V4A
Part No.: 318233
or equivalent.

Zertifikate

 

Technische Daten

Material of clamp StSt (V4A)
Clamping range Fl / Fl 30 / 30 mm
ASTM / AISI: 316Ti / 316L / 316
Dimensions 60 x 60 x 3 mm
Standard EN 62561-1
Short-circuit current (AC 50 Hz / DC) (1 s; ≤ 300 °C) 7.0 kA
*) See test certificate for exact classification.

Artikel 318233 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 318233 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Without intermediate plate, for two flat conductors up to 40 mm

1 Produkt

Art.-Nr. 320044 KS FL40 STTZN

GTIN 4013364021501, Zolltarifnr. (EU): 85359000, Bruttogewicht: 305.80 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

cross units without intermediate plate for two flat conductors up to 40 mm, HDG steel
Cross units for aboveground and
underground connections
for connecting conductors
in cross, parallel and T arrangement
Material of clamp: St/tZn
Clamping range Fl / Fl: 30-40 / 30-40 mm
Material of screw / nut: St/tZn
Standard: EN 62561-1

Brand: DEHN
Type: KS FL40 STTZN
Part No.: 320044
or equivalent.

Zertifikate

 

Technische Daten

Material of clamp St/tZn
Clamping range Fl / Fl 30-40 / 30-40 mm
Dimensions 70 x 70 x 3 mm
Standard EN 62561-1
Short-circuit current (AC 50 Hz / DC) (1 s; ≤ 300 °C) 12.6 kA
*) See test certificate for exact classification.

Artikel 320044 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 320044 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Without intermediate plate, for earth entries / air-termination rods

1 Produkt

Art.-Nr. 318252 KS 8.10 16 FL30 STTZN

GTIN 4013364048454, Zolltarifnr. (EU): 85359000, Bruttogewicht: 255.80 g, VPE: 25.00 pc(s)


Abbildungen

Weitere Information

Cross units without intermediate plate for earth entry rods / air-termination rods
Cross units for aboveground and
underground connections
for connecting conductors
in cross, parallel and T arrangement
Material of clamp: St/tZn
Clamping range Rd / Rd: 8-10 / 16 mm
Clamping range Rd / Fl: 16 / 30 mm
Material of screw / nut: St/tZn
Standard: EN 62561-1

Brand: DEHN
Type: KS 8.10 16 FL30 STTZN
Part No.: 318252
or equivalent.

Zertifikate

 

Technische Daten

Material of clamp St/tZn
Clamping range Rd / Rd 8-10 / 16 mm
Clamping range Rd / Fl 16 / 30 mm
Dimensions 60 x 60 x 3 mm
Standard EN 62561-1
*) See test certificate for exact classification.

Artikel 318252 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 318252 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

nach oben