DEHNguard YPV SCI ... – compact
![](/thumbor/unsafe/fit-in/480x/filters:fill(ffffff,false):quality(98)/dehn.de/store/f/44114510/HDVORSCHAU/950530a1_16-9.jpg)
![](/thumbor/unsafe/fit-in/1280x720/filters:fill(ffffff,false):quality(98)/dehn.de/store/f/44114510/HDVORSCHAU/950530a1_16-9.jpg)
- Prewired complete unit for use in photovoltaic systems
- Combined disconnection and short-circuiting device with safe electrical isolation (patented SCI principle)
- Tried and tested fault-resistant Y circuit of DEHNguard YPV SCI ... prevents damage to the surge protective device in case of insulation faults in the generator circuit
- Tested to EN 61643-31
- Suitable for use in all PV systems according to IEC 60364-7-712
Details
![](/thumbor/unsafe/fit-in/300x300/filters:fill(ffffff,false):quality(98)/dehn.de/store/f/44114511/HDVORSCHAU/952510_Schaltphasen_E.jpg)
![lorem ipsum](/thumbor/unsafe/fit-in/1280x/filters:fill(ffffff,false):quality(98)/dehn.de/store/f/44114511/HDVORSCHAU/952510_Schaltphasen_E.jpg)
Art.-Nr. 950531 DG YPV SCI 600
GTIN 4013364152953, Zolltarifnr. (EU): 85363030, Bruttogewicht: 296.00 g, VPE: 1.00 pc(s)
VorgängerTechnische Daten
SPD according to EN 61643-31 / IEC 61643-31 | type 2 / class II |
Max. PV voltage (UCPV ) | 600 V |
Short-circuit current rating (ISCPV ) | 1000 A |
Nominal discharge current (8/20 µs) [(DC+/DC-) --> PE] (In ) | 12.5 kA |
Max. discharge current (8/20 µs) [(DC+/DC-) --> PE] (Imax ) | 25 kA |
Voltage protection level (UP ) | ≤ 2.5 kV |
Approvals | KEMA, UL |
Art.-Nr. 950530 DG YPV SCI 1000
GTIN 4013364152960, Zolltarifnr. (EU): 85363030, Bruttogewicht: 321.00 g, VPE: 1.00 pc(s)
Technische Daten
SPD according to EN 61643-31 / IEC 61643-31 | type 2 / class II |
Max. PV voltage (UCPV ) | 1000 V |
Short-circuit current rating (ISCPV ) | 1000 A |
Nominal discharge current (8/20 µs) [(DC+/DC-) --> PE] (In ) | 12.5 kA |
Max. discharge current (8/20 µs) [(DC+/DC-) --> PE] (Imax ) | 25 kA |
Voltage protection level (UP ) | ≤ 4 kV |
Approvals | KEMA, UL |
Art.-Nr. 950536 DG YPV SCI 600 FM
GTIN 4013364154995, Zolltarifnr. (EU): 85363030, Bruttogewicht: 306.00 g, VPE: 1.00 pc(s)
VorgängerTechnische Daten
SPD according to EN 61643-31 / IEC 61643-31 | type 2 / class II |
Max. PV voltage (UCPV ) | 600 V |
Short-circuit current rating (ISCPV ) | 1000 A |
Nominal discharge current (8/20 µs) [(DC+/DC-) --> PE] (In ) | 12.5 kA |
Max. discharge current (8/20 µs) [(DC+/DC-) --> PE] (Imax ) | 25 kA |
Voltage protection level (UP ) | ≤ 2.5 kV |
Approvals | KEMA, UL |
Type of remote signalling contact | changeover contact |
Art.-Nr. 950535 DG YPV SCI 1000 FM
GTIN 4013364154988, Zolltarifnr. (EU): 85363030, Bruttogewicht: 331.00 g, VPE: 1.00 pc(s)
Technische Daten
SPD according to EN 61643-31 / IEC 61643-31 | type 2 / class II |
Max. PV voltage (UCPV ) | 1000 V |
Short-circuit current rating (ISCPV ) | 1000 A |
Nominal discharge current (8/20 µs) [(DC+/DC-) --> PE] (In ) | 12.5 kA |
Max. discharge current (8/20 µs) [(DC+/DC-) --> PE] (Imax ) | 25 kA |
Voltage protection level (UP ) | ≤ 4 kV |
Approvals | KEMA, UL |
Type of remote signalling contact | changeover contact |