DEHNbloc modular

  • Coordinated spark-gap-based lightning current arrester consisting of a base part and a plug-in protection module
  • Maximum system availability due to RADAX Flow follow current limitation
  • No tripping of 32 A gG fuses up to short-circuit currents of 50 kArms
  • Discharge capacity up to 50 kA (10/350 µs)
  • Directly coordinated with DEHNguard surge protective devices without additional cable length
  • Low voltage protection level
  • Operating state / fault indication by green / red indicator flag in the inspection window
  • Easy replacement of protection modules without tools due to module locking system with module release button

Details

lorem ipsum

DEHNbloc M 1 ...

Coordinated and modular single-pole lightning current arrester with a high discharge capacity.

3 Produkte

Art.-Nr. 961110 DB M 1 150

GTIN 4013364118560, Zolltarifnr. (EU): 85363090, Bruttogewicht: 333.40 g, VPE: 1.00 pc(s)

Vorgänger

Abbildungen

Weitere Information

Coordinated DEHNbloc M 1 150 lightning current arrester
Pluggable, coordinated and modular single-pole
lightning current arrester, width: 2 mod.
with high follow current limitation
Type 1 SPD according to EN 61643-11
RADAX Flow spark gap technology
for follow current limitation
Fault indication
Max. continuous operating voltage: 150 V a.c.
Voltage protection level: <= 1.5 kV
Lightning impulse current (10/350): 35 kA
Follow current extinguishing capability: up to 50 kArms
Energy-coordinated according to IEC 62305-4
with arresters of the Red/Line series

Brand: DEHN
Type: DB M 1 150
Part No.: 961110
or equivalent.

Zertifikate

 

Wellenbrecher-Funktion

Während des Ableitvorgangs fließt bei funkenstreckenbasierten Typ 1-Ableitern der gesamte Strom über den Typ-1 Ableiter. Wie bei einem Wellenbrecher wird die ankommende Energie stark heruntergebrochen, was die nachgeschalteten SPDs deutlich entlastet. Alle Typ 1-Ableiter der Red/Line-Produktfamilie weisen die Wellenbrecherfunktion WBF auf.

Technische Daten

SPD according to EN 61643-11 / IEC 61643-11 type 1 / class I
Max. continuous operating voltage (a.c.) (UC ) 150 V (50 / 60 Hz)
Lightning impulse current (10/350 µs) (Iimp ) 35 kA
Voltage protection level (UP ) ≤ 1.5 kV
Max. backup fuse (L) up to IK = 35 kArms (ta ≤ 0.2 s) 500 A gG
Max. backup fuse (L) up to IK = 35 kArms (ta ≤ 5 s) 315 A gG
Approvals UL, CSA

Artikel 961110 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 961110 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 961120 DB M 1 255

GTIN 4013364118614, Zolltarifnr. (EU): 85363090, Bruttogewicht: 355.80 g, VPE: 1.00 pc(s)

Vorgänger

Abbildungen

Weitere Information

Coordinated DEHNbloc M 1 255 lightning current arrester
Pluggable, coordinated and modular single-pole l
ightning current arrester, width: 2 mod.
with high follow current limitation
Type 1 SPD according to EN 61643-11
RADAX Flow spark gap technology
for follow current limitation
Fault indication
Max. continuous operating voltage: 255 V a.c.
Voltage protection level: <= 2.5 kV
Lightning impulse current (10/350): 50 kA
Follow current extinguishing capability: up to 100 kArms
Energy-coordinated according to IEC 62305-4
with arresters of the Red/Line series

Brand: DEHN
Type: DB M 1 255
Part No.: 961120
or equivalent.

Zertifikate

 

Wellenbrecher-Funktion

Während des Ableitvorgangs fließt bei funkenstreckenbasierten Typ 1-Ableitern der gesamte Strom über den Typ-1 Ableiter. Wie bei einem Wellenbrecher wird die ankommende Energie stark heruntergebrochen, was die nachgeschalteten SPDs deutlich entlastet. Alle Typ 1-Ableiter der Red/Line-Produktfamilie weisen die Wellenbrecherfunktion WBF auf.

Technische Daten

SPD according to EN 61643-11 / IEC 61643-11 type 1 / class I
Max. continuous operating voltage (a.c.) (UC ) 255 V (50 / 60 Hz)
Lightning impulse current (10/350 µs) (Iimp ) 50 kA
Voltage protection level (UP ) ≤ 2.5 kV
Max. backup fuse (L) up to IK = 50 kArms (ta ≤ 0.2 s) 500 A gG
Max. backup fuse (L) up to IK = 50 kArms (ta ≤ 5 s) 315 A gG
Approvals VDE, KEMA, UL

Artikel 961120 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 961120 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 961130 DB M 1 320

GTIN 4013364118638, Zolltarifnr. (EU): 85363090, Bruttogewicht: 341.00 g, VPE: 1.00 pc(s)

Vorgänger

Abbildungen

Weitere Information

Coordinated DEHNbloc M 1 320 lightning current arrester
Pluggable, coordinated and modular single-pole
lightning current arrester, width: 2 mod.
with high follow current limitation
Type 1 SPD according to EN 61643-11
RADAX Flow spark gap technology
for follow current limitation
Fault indication
Max. continuous operating voltage: 320 V a.c.
Voltage protection level: <= 2.5 kV
Lightning impulse current (10/350): 25 kA
Follow current extinguishing capability: up to 50 kArms
Energy-coordinated according to IEC 62305-4
with arresters of the Red/Line series

Brand: DEHN
Type: DB M 1 320
Part No.: 961130
or equivalent.

Zertifikate

 

Wellenbrecher-Funktion

Während des Ableitvorgangs fließt bei funkenstreckenbasierten Typ 1-Ableitern der gesamte Strom über den Typ-1 Ableiter. Wie bei einem Wellenbrecher wird die ankommende Energie stark heruntergebrochen, was die nachgeschalteten SPDs deutlich entlastet. Alle Typ 1-Ableiter der Red/Line-Produktfamilie weisen die Wellenbrecherfunktion WBF auf.

Technische Daten

SPD according to EN 61643-11 / IEC 61643-11 type 1 / class I
Max. continuous operating voltage (a.c.) (UC ) 320 V (50 / 60 Hz)
Lightning impulse current (10/350 µs) (Iimp ) 25 kA
Voltage protection level (UP ) ≤ 2.5 kV
Max. backup fuse (L) up to IK = 50 kArms (ta ≤ 0.2 s) 315 A gG
Max. backup fuse (L) up to IK = 50 kArms (ta ≤ 5 s) 315 A gG
Approvals UL

Artikel 961130 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 961130 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

DEHNbloc M 1 ... FM

Coordinated and modular single-pole lightning current arrester with a high discharge capacity; with remote signalling contact for monitoring system (floating changeover contact).

3 Produkte

Art.-Nr. 961115 DB M 1 150 FM

GTIN 4013364118577, Zolltarifnr. (EU): 85363090, Bruttogewicht: 337.30 g, VPE: 1.00 pc(s)

Vorgänger

Abbildungen

Weitere Information

Coordinated DEHNbloc M 1 150 FM lightning current arrester
Pluggable, coordinated and modular single-pole
lightning current arrester, width: 2 mod.
with high follow current limitation and remote signalling contact
Type 1 SPD according to EN 61643-11
RADAX Flow spark gap technology
for follow current limitation
Fault indication
Max. continuous operating voltage: 150 V a.c.
Voltage protection level: <= 1.5 kV
Lightning impulse current (10/350): 35 kA
Follow current extinguishing capability: up to 50 kArms
Energy-coordinated according to IEC 62305-4
with arresters of the Red/Line series

Brand: DEHN
Type: DB M 1 150 FM
Part No.: 961115
or equivalent.

Zertifikate

 

Wellenbrecher-Funktion

Während des Ableitvorgangs fließt bei funkenstreckenbasierten Typ 1-Ableitern der gesamte Strom über den Typ-1 Ableiter. Wie bei einem Wellenbrecher wird die ankommende Energie stark heruntergebrochen, was die nachgeschalteten SPDs deutlich entlastet. Alle Typ 1-Ableiter der Red/Line-Produktfamilie weisen die Wellenbrecherfunktion WBF auf.

Technische Daten

SPD according to EN 61643-11 / IEC 61643-11 type 1 / class I
Max. continuous operating voltage (a.c.) (UC ) 150 V (50 / 60 Hz)
Lightning impulse current (10/350 µs) (Iimp ) 35 kA
Voltage protection level (UP ) ≤ 1.5 kV
Max. backup fuse (L) up to IK = 35 kArms (ta ≤ 0.2 s) 500 A gG
Max. backup fuse (L) up to IK = 35 kArms (ta ≤ 5 s) 315 A gG
Approvals UL, CSA

Artikel 961115 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 961115 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 961125 DB M 1 255 FM

GTIN 4013364118621, Zolltarifnr. (EU): 85363090, Bruttogewicht: 359.30 g, VPE: 1.00 pc(s)

Vorgänger

Abbildungen

Weitere Information

Coordinated DEHNbloc M 1 255 FM lightning current arrester
Pluggable, coordinated and modular
single-pole lightning current arrester
with high follow current limitation and remote signalling contact
Type 1 SPD according to EN 61643-11
RADAX Flow spark gap technology
for follow current limitation
Fault indication
Max. continuous operating voltage: 255 V a.c.
Voltage protection level: <= 2.5 kV
Lightning impulse current (10/350): 50 kA
Follow current extinguishing capability: up to 100 kArms
Energy-coordinated according to IEC 62305-4
with arresters of the Red/Line series

Brand: DEHN
Type: DB M 1 255 FM
Part No.: 961125
or equivalent.

Zertifikate

 

Wellenbrecher-Funktion

Während des Ableitvorgangs fließt bei funkenstreckenbasierten Typ 1-Ableitern der gesamte Strom über den Typ-1 Ableiter. Wie bei einem Wellenbrecher wird die ankommende Energie stark heruntergebrochen, was die nachgeschalteten SPDs deutlich entlastet. Alle Typ 1-Ableiter der Red/Line-Produktfamilie weisen die Wellenbrecherfunktion WBF auf.

Technische Daten

SPD according to EN 61643-11 / IEC 61643-11 type 1 / class I
Max. continuous operating voltage (a.c.) (UC ) 255 V (50 / 60 Hz)
Lightning impulse current (10/350 µs) (Iimp ) 50 kA
Voltage protection level (UP ) ≤ 2.5 kV
Max. backup fuse (L) up to IK = 50 kArms (ta ≤ 0.2 s) 500 A gG
Max. backup fuse (L) up to IK = 50 kArms (ta ≤ 5 s) 315 A gG
Approvals VDE, KEMA, UL

Artikel 961125 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 961125 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

Art.-Nr. 961135 DB M 1 320 FM

GTIN 4013364118645, Zolltarifnr. (EU): 85363090, Bruttogewicht: 346.00 g, VPE: 1.00 pc(s)

Vorgänger

Abbildungen

Weitere Information

Coordinated DEHNbloc M 1 320 FM lightning current arrester
Pluggable, coordinated and modular
single-pole lightning current arrester
with high follow current limitation and remote signalling contact
Type 1 SPD according to EN 61643-11
RADAX Flow spark gap technology
for follow current limitation
Fault indication
Max. continuous operating voltage: 320 V a.c.
Voltage protection level: <= 2.5 kV
Lightning impulse current (10/350): 25 kA
Follow current extinguishing capability: up to 100 kArms
Energy-coordinated according to IEC 62305-4
with arresters of the Red/Line series

Brand: DEHN
Type: DB M 1 320 FM
Part No.: 961135
or equivalent.

Zertifikate

 

Wellenbrecher-Funktion

Während des Ableitvorgangs fließt bei funkenstreckenbasierten Typ 1-Ableitern der gesamte Strom über den Typ-1 Ableiter. Wie bei einem Wellenbrecher wird die ankommende Energie stark heruntergebrochen, was die nachgeschalteten SPDs deutlich entlastet. Alle Typ 1-Ableiter der Red/Line-Produktfamilie weisen die Wellenbrecherfunktion WBF auf.

Technische Daten

SPD according to EN 61643-11 / IEC 61643-11 type 1 / class I
Max. continuous operating voltage (a.c.) (UC ) 320 V (50 / 60 Hz)
Lightning impulse current (10/350 µs) (Iimp ) 25 kA
Voltage protection level (UP ) ≤ 2.5 kV
Max. backup fuse (L) up to IK = 50 kArms (ta ≤ 0.2 s) 315 A gG
Max. backup fuse (L) up to IK = 50 kArms (ta ≤ 5 s) 315 A gG
Approvals UL

Artikel 961135 wurde zum Merkzettel hinzugefügt.

Zum Merkzettel

Artikel 961135 wurde zum Warenkorb hinzugefügt.

Zum Warenkorb

nach oben